Keesun - Shenzhen Keesun Technology Co.,Ltd.
5G Antenna Solutions Manufacturer | ODM & OEM 
  Call Us
+86-18603053622
Coaxial Cable for Antennas: RG Vs LMR Vs Corrugated
You are here: Home » News » Technical Explainer Article » Coaxial Cable for Antennas: RG Vs LMR Vs Corrugated

Coaxial Cable for Antennas: RG Vs LMR Vs Corrugated

Views: 0     Author: Site Editor     Publish Time: 2026-11-17      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
sharethis sharing button

011.png

Coaxial Cable for Antennas: RG vs LMR vs Corrugated

An antenna is only as good as the path between it and the radio. You can buy a well-designed directional antenna, mount it in the clear, and still lose most of your signal in the cable that feeds it. That cable - the coaxial feed line - is one of the most underestimated parts of an RF system. It is also one of the few parts where a small upfront decision has a permanent effect on range, power, and reliability.

This guide compares the three families of coaxial cable for antenna work: traditional RG types, modern low-loss LMR-style cables, and corrugated air-dielectric cable. We explain what each is built from, how much signal each loses, and where each one earns its cost. We also cover impedance, shielding, power handling, and the installation details that decide whether a cable lasts a season or a decade. It is written to help you specify the right feed line, not to sell you the most expensive one.

What a Coaxial Cable Actually Does in an Antenna System

A coaxial cable carries radio frequency energy from the transmitter to the antenna, and the weak signal received by the antenna back to the receiver. It does this while keeping the energy inside the cable and keeping outside interference out. The name describes the construction: two conductors share the same axis, one inside the other, separated by an insulating layer.

The Four Layers of a Coax Cable

From the centre outward, a coax cable has a centre conductor, a dielectric insulator, a shield, and an outer jacket. The centre conductor carries the signal. The dielectric sets the impedance and the velocity factor, and its material drives much of the cable's loss. The shield - usually a woven braid, a foil, or a corrugated copper tube - forms the return path and blocks interference. The jacket protects everything from water, sunlight, and abrasion. Every difference between RG, LMR-style, and corrugated cable comes down to how these four layers are made.

Cable loss is measured in decibels and it applies in both directions. A feed line that loses 3 dB on transmit also loses 3 dB on receive, so the total round-trip penalty is 6 dB - a quarter of your power on each leg. Unlike a weak antenna, which you can sometimes compensate for with a higher-gain model, cable loss is paid whether the radio is transmitting or listening. That is why the feed line deserves a line in the link budget alongside antenna gain and path loss.

The Three Families: RG, LMR-Style, and Corrugated

The names you see on a cable datasheet come from different places. RG is a legacy military designation, LMR began as a manufacturer's brand and is now widely used as a generic label, and corrugated describes a construction method rather than a model number. Understanding that distinction helps you read specifications without getting trapped by a name.

RG Cables: The Legacy Flexible Standard

RG cables are the thin, flexible coax most people picture when they think of a coaxial cable. Common 50-ohm types include RG-58 and the thicker RG-213, while RG-59 and RG-6 are 75-ohm types used for video and cable television rather than antennas. RG cables use a braided shield and a fairly simple dielectric, which makes them cheap, easy to route, and easy to terminate. The trade-off is loss: above a few hundred megahertz, a thin RG cable can lose more signal per metre than the antenna itself gains. RG-174 and RG-58 are fine for short jumpers, GPS pigtails, and indoor equipment. They are a poor choice for a long run at UHF or microwave frequencies.

LMR-Style: Modern Flexible Low-Loss Cable

LMR-style cables keep the flexibility of RG but rebuild the layers for lower loss. They use a foamed dielectric with a high velocity factor, a bonded aluminium foil over the braid for better shielding, and a tough outer jacket. The result is a cable that is still easy to bend and terminate but loses roughly half as much signal as a comparable RG type. Sizes such as LMR-240, LMR-400, and LMR-600 cover everything from drone and GNSS installations to fixed base-station feeds. Because several manufacturers make compatible cable, check the exact attenuation figures on the datasheet rather than assuming all cables with an LMR-style label are identical.

Corrugated cable replaces the braid with a formed copper tube and uses air, often held in a foam or helical spacer, as most of the dielectric. Air has far lower loss than solid plastic, so a corrugated feed line can deliver signal with very little attenuation even at microwave frequencies. Common sizes are described by the approximate outer diameter of the cable, such as half inch, seven eighths, and inch and a quarter. Corrugated cable is stiffer, heavier, more expensive, and needs more care at the bend, but for a permanent tower or rooftop run it is often the only way to keep loss acceptable. It is also the standard choice where low passive intermodulation matters.

Attenuation: The Number That Decides Your Cable

Attenuation is the loss of signal as it travels along the cable, normally quoted in decibels per 100 feet or per 100 metres at a stated frequency. It is the first specification to look at, because it sets a hard floor on system performance. Attenuation rises with frequency and with length, so a cable that is excellent at 900 MHz may be disappointing at 5.8 GHz, and a loss figure that looks small per metre adds up quickly over a thirty-metre tower run.

How Frequency Changes Loss

Loss does not grow in a straight line with frequency; it rises roughly with the square root of frequency for a given cable construction. This is why a cable specified for a VHF or 900 MHz system cannot be judged on that figure alone when you move to 2.4 GHz or 5 GHz Wi-Fi and drone bands. Always compare cables at the frequency you will actually use. If a supplier quotes attenuation without a frequency, ask for it - the number is meaningless on its own.

A Typical Coaxial Cable Attenuation Comparison

The figures below are representative published values at 2.4 GHz, expressed in dB per 100 feet. They are intended to show the scale of the differences between families, not to replace a manufacturer's datasheet, and they will vary by brand and exact construction:

RG-58, thin 50-ohm flexible: roughly 10 to 13 dB per 100 ft - acceptable for a short jumper, costly over a long run.

RG-213, thicker braided 50-ohm: roughly 5 to 6 dB per 100 ft - better than RG-58 but still lossy at microwave frequencies.

LMR-240-style flexible: roughly 6 to 7 dB per 100 ft - a good compromise where space is tight.

LMR-400-style flexible: roughly 3.8 to 4.0 dB per 100 ft - the common choice for fixed 2.4 GHz links.

LMR-600-style flexible: roughly 2.5 to 2.7 dB per 100 ft - lower loss, at the cost of a thicker, stiffer cable.

Half-inch corrugated air dielectric: roughly 1.5 to 1.8 dB per 100 ft - the standard for tower and rooftop feeds.

Seven-eighth-inch corrugated: roughly 0.9 to 1.1 dB per 100 ft - used where every tenth of a dB counts.

Read those numbers as system decisions. Cutting a run from 100 feet to 50 feet saves the same loss as moving up a cable size, and shortening the cable is usually cheaper. Where the run cannot move, spend the money on a lower-loss cable or consider placing the radio closer to the antenna and running a fibre or data link instead of RF.

dB per 100 Feet, per Metre, or per 100 Metres

Datasheets use different units, and mixing them is an easy way to order the wrong cable. One hundred feet is about 30.5 metres. Convert the quoted loss to your actual run length before you compare options, and be clear about whether the figure covers one cable or a pair. Two coax cables used together for a transmit and receive path each carry their own loss; the loss is not shared between them.

Impedance: Why 50 Ohm Is the Antenna Default

Coaxial cable comes mainly in 50-ohm and 75-ohm versions. RF and microwave antennas, transmitters, and test equipment are built around 50 ohms, while 75 ohms belongs to video and cable television distribution. The number describes the ratio of the conductor and dielectric dimensions, so you cannot tell by looking at a connector whether a cable is 50 or 75 ohms - some 75-ohm RG types use the same connectors as their 50-ohm cousins.

Connecting a 75-ohm cable to a 50-ohm antenna creates a mismatch at the junction. The reflection coefficient is about 0.2, giving a voltage standing wave ratio near 1.5:1 and roughly 0.2 dB of mismatch loss in each direction. That may sound small, but it is a loss you pay for nothing, and it sits on top of the cable's own attenuation. Specify 50-ohm cable for every antenna feed unless the equipment manufacturer says otherwise.

Shielding, PIM, and Power Handling

Attenuation is not the only specification that matters. A cable also has to keep its signal to itself, survive the power you put through it, and avoid generating interference of its own.

Shield Effectiveness and Interference

A braided shield alone leaves small gaps that let high-frequency energy leak in and out. Foiled cables add a continuous metal layer over the braid, and corrugated copper is effectively solid. Good shielding matters most in electrically noisy places - near motors, switching power supplies, and other transmitters - and on receive, where a weak signal can be drowned by interference picked up along the run. Double-shielded and foil-plus-braid constructions cost more but protect the link in environments where a single braid would not.

Passive Intermodulation in High-Power Feeds

Passive intermodulation, usually shortened to PIM, is interference generated by the cable and connectors themselves when two or more high-power carriers share a feed line. Rusty joints, loose connections, mixed metals, and poor-quality braid can all act like tiny diodes and create new frequencies that land in the receive band. It is a particular problem in cellular base stations, where a macro site carrying several carriers can lose receiver sensitivity to its own feed line. Low-PIM cable and connectors, clean assembly, and careful torque control are the remedy. If you are building a multi-carrier site, specify a low-PIM cable and matching connectors from the start rather than trying to fix the problem after installation.

Power Handling and Voltage Rating

Every cable has a maximum voltage and a power-handling limit that falls with frequency. Thin cables heat up under high power, and the dielectric can break down if the voltage is high enough. For receive-only antennas and low-power radios this is rarely a constraint. For a high-power transmitter or a broadcast feed it is a primary specification, and it is another reason to step up to a thicker cable or a corrugated line. Check both the continuous power rating and the peak voltage rating, especially where a high-power amplifier is involved.

Flexibility, Bend Radius, and Installation Reality

A cable that performs perfectly on a datasheet can be ruined by the way it is installed. Every cable has a minimum bend radius, usually expressed as a multiple of its outer diameter. Bend it tighter and you deform the dielectric and the shield, which changes the impedance at that point and creates a reflection. Flexible RG and LMR-style cables tolerate tight bends and are the right choice where the route is crowded or the antenna moves, such as on a drone or a hand-held system. Corrugated cable needs gentle bends and proper support clips, but it holds its shape on a long vertical run and resists crushing.

Termination is the other half of installation. A poorly fitted connector adds loss and a reflection at exactly the point where the cable meets the antenna, and it is a common source of water ingress. Match the connector to the cable precisely - an SMA connector might suit a thin flexible cable on a drone, while an N-Type or a 7-16 DIN connector suits a larger flexible or corrugated feed at a base station. Use the correct crimp or compression tool and follow the manufacturer's assembly instructions.

Outdoor, Direct-Burial, and Plenum Ratings

The jacket matters as much as the RF performance. A cable intended for outdoor use needs a UV-resistant jacket that will not crack in sunlight, and a flooded or gel-filled core if water could reach the dielectric. Water inside a coax cable raises loss dramatically and can ruin a run from the inside out. Direct-burial cable has a tougher, often armoured jacket and a filling compound that stops water moving along the cable if the sheath is damaged. Indoor runs in air-handling spaces may require a plenum-rated jacket that meets fire and smoke rules. Choose the jacket for the environment first, then compare the RF numbers among cables that are rated for the job.

How to Choose: A Practical Decision Path

Work through these questions in order and the right family usually becomes clear:

How long is the run? Under a few metres at UHF, a good flexible cable is fine. Long runs at microwave frequencies push you toward low-loss or corrugated cable.

What frequency? Compare attenuation at your actual operating frequency, not at the lowest frequency on the datasheet.

Does the installation move? Vibrating or repositioned cables need flexible RG or LMR-style cable; a fixed tower run can use corrugated.

Is it a high-power or multi-carrier site? Specify power handling and low PIM, and pair the cable with low-PIM connectors.

What is the environment? Match the jacket to outdoor, buried, or plenum conditions before comparing loss figures.

What can you terminate correctly? A premium cable with a badly fitted connector performs worse than a modest cable fitted properly.

In short: use thin RG for short jumpers and pigtails, LMR-style flexible cable for most flexible and medium-length antenna runs, and corrugated cable for permanent, long, or high-performance links where loss and PIM have to be kept to a minimum.

Common Mistakes to Avoid

Choosing cable by connector shape alone, without checking whether it is 50 or 75 ohms.

Comparing attenuation figures quoted at different frequencies or in different units.

Ignoring connector loss: two connectors can cost as much as several metres of cable.

Bending a corrugated cable tighter than its minimum radius to make a route fit.

Using indoor cable outdoors, or non-flooded cable in a run where water can collect.

Mixing metals or leaving joints loose on a high-power multi-carrier feed, which invites PIM.

Assuming the most expensive cable is the right one when a shorter route would solve the loss problem for less.

Conclusion

There is no single best coaxial cable for antenna work - there is the right cable for a given frequency, run length, power level, and installation. RG types are cheap and flexible but lossy at higher frequencies. LMR-style cables cut that loss while staying easy to handle and are the default for most antenna feeds. Corrugated air-dielectric cable delivers the lowest loss and best PIM performance for permanent, high-performance links. Decide on attenuation at your operating frequency, keep the path at 50 ohms, protect it from water and bending, and fit the right connectors. Do those things and the feed line will stop being the weak link in your RF system.

For the wider picture, start with our antenna selection guide, which covers reach, beamwidth, and polarization before you choose a feed line. Our coaxial cables and RF connectors overview introduces the parts covered in depth here, and the RF connector types guide compares SMA, N-Type, and 7-16 DIN choices for termination. The antenna gain, antenna polarization, and antenna VSWR explainers cover the datasheet specs that sit alongside cable loss in a link budget. Our base station antenna series shows where corrugated, low-PIM feeds matter, while the drone video transmission and UAV GNSS guides show how flexible cable choices play out when weight and space are tight.

Shenzhen Keesun Technology Co.,Ltd was founded in Aug of 2012, a high-tech enterprise specializing in various types of antenna and network cable manufacturing.